3.14 Power Failure Connections
3.14.1 Power Failure Connections
When the power supply to the PBX fails, power failure transfer (PFT) will switch from the current connection to the Power Failure Connection. Refer to "1.13.11 Power Failure Transfer" in the Feature Manual for further information. |
Connection
Power Failure Connection connects a specific SLT and a CO line in the event of power failure. The following analog CO line and extension cards can be used for Power Failure Connections: |
• |
Analog CO line cards: LCOT16 (4 PFT ports) and LCOT8 (2 PFT ports) |
• |
Extension cards: MSLC16 (4 PFT ports), CSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT ports) and SLC8 (2 PFT ports) |
|
To 1 analog CO line card, connect only 1 extension card. |
Note
|
By programming the PBX, a CO line conversation established during power failure can be maintained even when the power returns and the connection is switched back to the normal configuration from the Power Failure Connection. However, if no special programming is performed, the connection will be dropped when power returns.
|
|
|
Accessories and User-supplied Items
|
Accessories (included): none |
User-supplied (not included): RJ11 connectors |
RJ11 Connector Pin Assignments for Analog CO Line Card
|
PFT Ports 1 and 2 |
|
PFT Ports 3 and 4 (for LCOT16 card only) |
|
RJ11 Connector Pin Assignments for Extension Card
|
PFT Ports 1 and 2 |
|
PFT Ports 3 and 4 (for MSLC16/CSLC16/SLC16 card only) |
|